Free tool · no sign-upHome planning
Water Heater Size Calculator
Convert household size, bathrooms and bathing pattern into hot-water demand, then compare storage and instantaneous options.
Assumptions reviewed:
10 L base plus 15 L per person.
Advanced options
Result
- Daily hot-water need
- 70 L
- Number of heaters
- 2
- Power per unit
- 1.5 kW
- Monthly consumption
- 212.4 kWh/month
- Estimated monthly running cost
- EGP 463
- Equipment price
- EGP 2,600 – EGP 7,600
- Required electrical line
- 2.5 mm² · 20A breaker
Planning estimate based on litres per person and daily tank reheats. Electricity uses progressive residential tariffs from August 2026; gas price is editable.
We do not save your inputs. The result stays in the link and on your device.
How it works and assumptions
- Daily demand starts at 10 L plus 15 L per person and adjusts for baths.
- Storage capacity is divided by the chosen distribution and rounded up to commercial tank sizes; large central demand can split across two heaters.
- Gas and instant-electric outputs are sized to flow, while storage electric uses tank power and reheats per day.
- Monthly energy is priced on the electricity tariff or the editable gas rate.
- Base + per person
- 10 L + 15 L/person
- Default tank reheats
- 1.5/day
- Instant electric line
- 11 kW; 6 mm²; 40A breaker
Frequently asked questions
What heater size does a family of four need?
Demand is about 70 L/day for showers. Two local heaters need roughly 40 L each; one central unit needs about 80 L.
Bath use raises demand.
One heater per bathroom or one central heater?
Local heaters give faster hot water, shorter pipes and redundancy. A central heater saves equipment and space when bathrooms and kitchen are close, but large capacities heat slowly and can be heavy.
Is gas cheaper to run than electricity?
Usually, but gas requires permanent ventilation and a safe exhaust flue and must not be installed in a sealed bathroom. Compare actual tariffs and equipment/installation costs.
What electrical supply does an instant heater need?
A typical 11 kW unit needs a dedicated 6 mm² circuit and 40A breaker, and an older apartment supply may not support it. Have an electrician verify the service and protection.
What thermostat temperature should I use?
About 55–60°C balances hygiene, scale and losses. Higher settings increase heat loss and limescale; switch off for multi-day absences and maintain the safety valve.