Free tool · no sign-upFinishing and quantities
Electrical Points and Wiring Calculator
Build a point schedule from room counts, then turn it into dedicated circuits, cable sizes, 100-metre rolls and a distribution board.
Assumptions reviewed:
2 lighting and 5 socket points per room.
Advanced options
Uses 6 mm² cable and a 32A breaker.
Result
- Lighting (2 circuits)
- 16 points
- Sockets and appliances (6 circuits)
- 40 points
- TV/data
- 1 points
- AC and heater dedicated lines
- 3 points
- Breakers plus 63A main
- 11 + 1
- Distribution board
- 18 ways
- Estimated conduit
- 300–420 m
- Cable
- EGP 43,400 – EGP 47,395
- Breakers and board
- EGP 1,325 – EGP 2,970
- Switches and sockets (49 units)
- EGP 1,470 – EGP 5,880
- Labour
- EGP 3,450 – EGP 9,650
- Estimated total
- EGP 49,645 – EGP 65,895
- All-in market point reference
- EGP 18,000 – EGP 36,000
| Cable | Use | Metres / rolls |
|---|---|---|
| 1.5 mm² | Lighting | 288 m / 3 |
| 2.5 mm² | Sockets, appliances and heater | 1,365 m / 14 |
| 4 mm² | AC up to 2.25 hp | 108 m / 2 |
Planning estimate using standard points per room and average cable runs. The market definition of an all-in point varies and may exclude first-tier cable brands.
We do not save your inputs. The result stays in the link and on your device.
How it works and assumptions
- Room counts generate lighting, socket, appliance and TV/data points; AC and heaters add dedicated points.
- Circuits allow 9 lighting or 7 socket points, plus one line per AC and heater.
- Cable lengths use average route lengths and round up to 100 m rolls for each cross-section.
- Materials combine cable, breakers, board and switch level; labour is calculated by point type and board.
- Lighting / socket cable
- 1.5 / 2.5 mm²
- Small / large AC cable
- 4 / 6 mm²
- Cable per point
- 18 m lighting; 33 m sockets; 54 m AC
- All-in market point
- EGP 300–600
Frequently asked questions
How many electrical points does a three-bedroom apartment need?
A typical three-bedroom apartment with reception, kitchen, two bathrooms, hall, two AC units and one heater produces about 60 points in this model. Your furniture and appliance plan should set the final socket count.
Can sockets use 1.5 mm² cable?
No. 1.5 mm² is for lighting; sockets use 2.5 mm² with a 16A breaker.
AC and heaters need their specified dedicated circuits.
How many sockets may share one breaker?
The Egyptian code limit is 10 outlets; the calculator uses 7 socket points and 9 lighting points per circuit.
What heights are usual for switches and sockets?
Typical finished-floor heights are 110–120 cm for switches, 30–40 cm for ordinary sockets, 110–120 cm above kitchen counters and about 2.2 m for an AC outlet. Coordinate with furniture first.
Why photograph cable routes before plastering?
Conduits disappear after plaster. Photos and a marked plan prevent later drilling into cables and help future repairs; also retain spare empty conduit routes from the board.