Electrical Points and Wiring Calculator

Build a point schedule from room counts, then turn it into dedicated circuits, cable sizes, 100-metre rolls and a distribution board.

Assumptions reviewed:

Bedrooms
3

2 lighting and 5 socket points per room.

Living/reception rooms
1
Kitchens
1
Bathrooms
2
Halls, corridors or balconies
1
Air conditioners
2
Electric water heaters
1
Apartment area (m²)

Used to size the distribution board and estimate conduit.

Switch and socket level
Advanced options
AC units of 3 hp or more
0

Uses 6 mm² cable and a 32A breaker.

Result

Total electrical points
60 points
Materials and labour: about EGP 49,645 – EGP 65,895
Lighting (2 circuits)
16 points
Sockets and appliances (6 circuits)
40 points
TV/data
1 points
AC and heater dedicated lines
3 points
Breakers plus 63A main
11 + 1
Distribution board
18 ways
Estimated conduit
300–420 m
Cable
EGP 43,400 – EGP 47,395
Breakers and board
EGP 1,325 – EGP 2,970
Switches and sockets (49 units)
EGP 1,470 – EGP 5,880
Labour
EGP 3,450 – EGP 9,650
Estimated total
EGP 49,645 – EGP 65,895
All-in market point reference
EGP 18,000 – EGP 36,000
CableUseMetres / rolls
1.5 mm²Lighting288 m / 3
2.5 mm²Sockets, appliances and heater1,365 m / 14
4 mm²AC up to 2.25 hp108 m / 2

Planning estimate using standard points per room and average cable runs. The market definition of an all-in point varies and may exclude first-tier cable brands.

We do not save your inputs. The result stays in the link and on your device.

How it works and assumptions

  1. Room counts generate lighting, socket, appliance and TV/data points; AC and heaters add dedicated points.
  2. Circuits allow 9 lighting or 7 socket points, plus one line per AC and heater.
  3. Cable lengths use average route lengths and round up to 100 m rolls for each cross-section.
  4. Materials combine cable, breakers, board and switch level; labour is calculated by point type and board.
Dated inputs used by this calculator
Lighting / socket cable
1.5 / 2.5 mm²
Egyptian electrical code and market practice. Reviewed 2026-09-25.
Small / large AC cable
4 / 6 mm²
Egyptian electrical code and market practice. Reviewed 2026-09-25.
Cable per point
18 m lighting; 33 m sockets; 54 m AC
Average route length multiplied by conductors. Reviewed 2026-09-25.
All-in market point
EGP 300–600
HomeRun requests, 2026; inclusions vary. Reviewed 2026-09-25.

Frequently asked questions

How many electrical points does a three-bedroom apartment need?

A typical three-bedroom apartment with reception, kitchen, two bathrooms, hall, two AC units and one heater produces about 60 points in this model. Your furniture and appliance plan should set the final socket count.

Can sockets use 1.5 mm² cable?

No. 1.5 mm² is for lighting; sockets use 2.5 mm² with a 16A breaker.

AC and heaters need their specified dedicated circuits.

How many sockets may share one breaker?

The Egyptian code limit is 10 outlets; the calculator uses 7 socket points and 9 lighting points per circuit.

What heights are usual for switches and sockets?

Typical finished-floor heights are 110–120 cm for switches, 30–40 cm for ordinary sockets, 110–120 cm above kitchen counters and about 2.2 m for an AC outlet. Coordinate with furniture first.

Why photograph cable routes before plastering?

Conduits disappear after plaster. Photos and a marked plan prevent later drilling into cables and help future repairs; also retain spare empty conduit routes from the board.